An acoustic water leak detector that picks up the sound of water escaping from pipes with dedicated indoor and outdoor sensors. One unit covers water supply and hot-water pipes in homes and commercial buildings, underfloor heating pipes and outdoor pipes around buildings.
An indoor sensor picks up sound through walls and floors, and an outdoor sensor is placed on the ground. The unit recognizes the connected sensor automatically and remembers the frequency mode and screen brightness for each sensor.
Choose Indoor Mode 1, Indoor Mode 2, Outdoor or Custom to focus on the band where leak sounds are easiest to hear for the site and pipe conditions.
Analyzes the collected sound data and indicates on screen when a leak is likely, so you can confirm you are getting closer without relying on listening experience alone (Indoor Modes 1 and 2).
Quick mode is the basic mode for listening along the pipe. Inspection mode records and compares the sound pressure at several points to find the point closest to the leak.
Save the detection screen (sound pressure level and spectrum) as JPEG and the detected sound as .wav on the device for reporting and sharing.
Work while watching the spectrum and volume on a 7-inch 1024×600 touchscreen. Battery operating time is 11 hours with a 4-hour charging time.
Switch frequency modes with the right button. Choose the band where leak sounds are easiest to hear for the sensor in use and the site conditions.




*SuperDetect is available in Indoor Mode 1 and Indoor Mode 2 only. The reset button requires a 3-second press, preventing settings from being cleared by accident.
A typical survey procedure with the AD22P. A leak makes a hissing, ticking sound that gets louder as you approach the leak point.
Early morning or late night, when it is quiet, is recommended. Avoid rain, strong wind and rush hour.
Close the main valve, stop valves and faucets, pressurize the pipes with a pressure pump and watch the gauge. If the pressure drops there is a leak somewhere in the building; if it holds there is no leak.
Inspect visible pipes by eye and by touch for leaks.
Get an up-to-date drawing of the pipes. For pipes embedded in floors or walls, run hot water through them and locate them with a thermal imaging camera.
Pressurize the pipe with air to 0.4–0.6 MPa using an air pump. Connect the indoor sensor, select Indoor Mode 1 or 2 and listen while moving the sensor along the pipe.
The point where the sound is loudest and the on-screen spectrum and volume peak and stay stable is close to the leak. When SuperDetect shows that a leak is likely, you are getting close. Adjust the volume with the left wheel.
Set several detection points along the pipe and collect the sound at each one. Tap Analyze to find the point closest to the leak. Quick mode is enough in most cases; Inspection mode is used when you want to record and compare sound pressure at each point.
As indoors, quiet early morning or late night is recommended. Avoid rain, strong wind and rush hour.
Get a drawing of the outdoor pipes and confirm where they run.
Connect the outdoor sensor, select Outdoor mode and listen while placing the sensor on the ground along the pipe route. Look for the point where the sound, spectrum and volume peak.
As indoors, record and compare sound pressure at several points along the pipe to find the point closest to the leak.
Save the detection screen and sound on the device.


| Model | HIKMICRO AD22P |
|---|---|
| Category | Acoustic water leak detector (indoor / outdoor) |
| Frequency Range | 200–16,000 Hz |
| Frequency Modes | Indoor Mode 1: 5,000–16,000 Hz / Indoor Mode 2: 8,000–16,000 Hz / Outdoor: 200–2,000 Hz / Custom: 200–16,000 Hz (100 Hz steps) |
| Amplification | Manual |
| SuperDetect | Supported (Indoor Modes 1 and 2) |
| Detection Modes | Quick / Inspection |
| Sensors | Indoor sensor / outdoor sensor (automatic recognition) |
| Display | 7-inch LCD touchscreen (1024×600) |
| Screen Brightness | Manual / Auto |
| Recording | Screenshot (JPEG) / audio (.wav, playback on PC) |
| Interface | USB Type-C (USB 2.0) |
| Battery | Rechargeable Li-ion battery |
| Operating Time | 11 h |
| Charging Time | 4 h |
| Ingress Protection | Main unit IP40 / indoor sensor IP40 / outdoor sensor IP66 |
| Drop Test | 1.2 m |
| Operating Temperature | -10 to 50 °C |
| Storage Temperature | -40 to 70 °C |
| Relative Humidity | Below 90% (non-condensing) |
| EMC | EN 55032, EN 55035, EN IEC 61000-3-2, EN 61000-3-3, EN IEC 61326-1 |
| Weight | Main unit 712 g / grip 305 g / headset 190 g / indoor sensor 340 g / outdoor sensor 318 g / listening sticks 79 g, 158 g, 160 g |
Contact us about demo units or for a proposal suited to the pipes you need to survey and your site conditions.
Model AD22P